A detailed comparison of 100GBASE-LR4 and other major 100G optical transceiver types, including IR4 (CWDM4) , DR4, and GR4 (PSM4)

LPO

100GBASE-LR4 vs Other 100G Modules: LR4 vs IR4 (CWDM4) vs DR4 vs GR4 (PSM4)

A detailed comparison of 100GBASE-LR4 and other major 100G optical transceiver types, including IR4 (CWDM4) , DR4, and GR4 (PSM4) .

Note on naming: “IR4” typically refers to 100GBASE-CWDM4 (2km). “GR4” is not an official IEEE standard and generally refers to the 100G PSM4 (parallel single-mode) solution.


100G Module Comparison Table (Without SR4)

Feature100G PSM4 (GR4)100GBASE-CWDM4 (IR4)100GBASE-LR4100GBASE-DR4
IEEE / MSA StandardPSM4 MSACWDM4 MSA802.3ba802.3cd
Max Distance2 km (500m for older versions)2 km10 km500 m
Fiber TypeSingle-Mode (SMF)Single-Mode (SMF)Single-Mode (SMF)Single-Mode (SMF)
Connector TypeMPO-12 (8 fibers)Duplex LC (2 fibers)Duplex LC (2 fibers)Duplex LC (2 fibers)
Core TechnologyParallel (4 lanes: 4x25G)CWDM (Coarse WDM, 4 wavelengths)LAN-WDM (Dense WDM, 4 wavelengths)Single-wavelength PAM4 modulation
Wavelengths1310 nm (single)1271, 1291, 1311, 1331 nm~1295-1310 nm (tighter spacing)1310 nm
Fiber UsageHigh (8 fibers)Low (2 fibers)Low (2 fibers)Low (2 fibers)
Relative CostLowMediumHighMedium
Breakout Capable?Yes (1x100G to 4x25G)NoNoNo
Power Consumption~2-3W~3-4W~4-5W~3-4W

Detailed Comparison

100G PSM4 (Often Referred to as “GR4”)

AspectDetail
Full NameParallel Single-Mode 4-lane
Max Distance2 km (standard), 500m (early versions)
ConnectorMPO-12 (8 fibers: 4 TX + 4 RX)
TechnologyFour independent 25G channels at 1310nm over parallel fibers

Pros:

  • Lower cost than LR4
  • Supports breakout – one 100G port can connect to four 25G ports (e.g., 4x SFP28)
  • Simple technology, widely available

Cons:

  • Consumes 8 fibers – inefficient for fiber-scarce environments
  • MPO connectors are larger and less common than LC
  • Shorter distance than LR4 (2km vs 10km)

Best for: Data center breakout applications where fiber count is not a constraint.


100GBASE-CWDM4 (IR4)

AspectDetail
Full NameCoarse Wavelength Division Multiplexing 4-lane
Max Distance2 km
ConnectorDuplex LC (2 fibers)
TechnologyFour CWDM wavelengths (1271/1291/1311/1331 nm) multiplexed onto one fiber pair

Pros:

  • Uses only 2 fibers – great for existing LC duplex infrastructure
  • Standard LC connectors – no cable replacement needed
  • Lower cost than LR4
  • Perfect for 2km campus/DC interconnect

Cons:

  • Limited to 2km – cannot reach 10km
  • More expensive than PSM4
  • No breakout capability

Best for: Upgrading existing duplex SMF links to 100G within 2km.


100GBASE-LR4 (The Long-Reach Standard)

AspectDetail
Full NameLong-Reach 4-lane (LAN-WDM)
Max Distance10 km
ConnectorDuplex LC (2 fibers)
TechnologyFour LAN-WDM wavelengths (tighter spacing than CWDM) multiplexed onto one fiber pair

Pros:

  • Longest distance – 10km standard (can reach 20km+ with some modules)
  • Only 2 fibers – efficient fiber utilization
  • Standard LC connectors – drop-in replacement for existing LX/LH infrastructure
  • Mature, proven technology – widely deployed

Cons:

  • Highest cost among these options
  • Higher power consumption (~4-5W)
  • No breakout support

Best for: Metro networks, campus backbone, data center interconnect (DCI), and any long-haul 100G application up to 10km.


100GBASE-DR4 (Next-Generation)

AspectDetail
Full Name4-lane Dielectric Refractive (PAM4)
Max Distance500 m
ConnectorDuplex LC (2 fibers)
TechnologySingle-wavelength 1310nm using PAM4 modulation (4-level amplitude)

Pros:

  • Future-proof – building block for 400G-DR4 (4x100G)
  • Uses only 2 fibers with LC connectors
  • Lower cost per Gbps compared to LR4 at shorter distances
  • Good for 400G transition strategy

Cons:

  • 500m maximum – shorter than LR4 and CWDM4
  • Requires FEC (Forward Error Correction) on the host switch – not all switches support it
  • Newer technology – less field-proven than LR4

Best for: New data center builds where future 400G upgrade is planned, and distances are under 500m.


Quick Decision Guide

Step 1: What is your required distance?

DistanceRecommended Module
≤ 500mDR4 (if switch supports FEC) or PSM4
≤ 2kmCWDM4 (IR4) or PSM4
≤ 10kmLR4 (clear choice)

Step 2: What is your fiber infrastructure?

Fiber Type / ConnectorBest Module
Duplex LC SMF (2 fibers)CWDM4 (≤2km) or LR4 (≤10km) or DR4 (≤500m)
MPO-12 SMF (8+ fibers)PSM4 (GR4)

Step 3: Do you need breakout capability?

NeedRecommendation
Yes – one 100G port to four 25G portsPSM4 (GR4)
No – point-to-point 100G onlyCWDM4, LR4, or DR4

Summary & Recommendations

If you need…Choose…
10km long-distance over duplex SMF100GBASE-LR4 – the only standard option
2km distance with existing duplex LC fiber100GBASE-CWDM4 (IR4) – best balance of cost and performance
2km distance with MPO fiber infrastructure and breakout capability100G PSM4 (GR4) – lower cost, breakout ready
500m distance in a new data center planning for 400G100GBASE-DR4 – future-proof foundation
Lowest cost for short links (<500m) with FEC-capable switches100GBASE-DR4

Final Word

  • For 10km links → 100GBASE-LR4 is your only real choice. It’s the proven, mature standard for long-distance 100G.
  • For 2km links with LC duplex fiber → 100GBASE-CWDM4 (IR4) is usually the sweet spot.
  • For 2km links with MPO fiber and breakout needs → 100G PSM4 (GR4) .
  • For future 400G-ready builds under 500m → 100GBASE-DR4 .