100GBASE-LR4 vs Other 100G Modules: LR4 vs IR4 (CWDM4) vs DR4 vs GR4 (PSM4)
A detailed comparison of 100GBASE-LR4 and other major 100G optical transceiver types, including IR4 (CWDM4) , DR4, and GR4 (PSM4) .
Note on naming: “IR4” typically refers to 100GBASE-CWDM4 (2km). “GR4” is not an official IEEE standard and generally refers to the 100G PSM4 (parallel single-mode) solution.
100G Module Comparison Table (Without SR4)
| Feature | 100G PSM4 (GR4) | 100GBASE-CWDM4 (IR4) | 100GBASE-LR4 | 100GBASE-DR4 |
|---|---|---|---|---|
| IEEE / MSA Standard | PSM4 MSA | CWDM4 MSA | 802.3ba | 802.3cd |
| Max Distance | 2 km (500m for older versions) | 2 km | 10 km | 500 m |
| Fiber Type | Single-Mode (SMF) | Single-Mode (SMF) | Single-Mode (SMF) | Single-Mode (SMF) |
| Connector Type | MPO-12 (8 fibers) | Duplex LC (2 fibers) | Duplex LC (2 fibers) | Duplex LC (2 fibers) |
| Core Technology | Parallel (4 lanes: 4x25G) | CWDM (Coarse WDM, 4 wavelengths) | LAN-WDM (Dense WDM, 4 wavelengths) | Single-wavelength PAM4 modulation |
| Wavelengths | 1310 nm (single) | 1271, 1291, 1311, 1331 nm | ~1295-1310 nm (tighter spacing) | 1310 nm |
| Fiber Usage | High (8 fibers) | Low (2 fibers) | Low (2 fibers) | Low (2 fibers) |
| Relative Cost | Low | Medium | High | Medium |
| Breakout Capable? | Yes (1x100G to 4x25G) | No | No | No |
| Power Consumption | ~2-3W | ~3-4W | ~4-5W | ~3-4W |
Detailed Comparison
100G PSM4 (Often Referred to as “GR4”)
| Aspect | Detail |
|---|---|
| Full Name | Parallel Single-Mode 4-lane |
| Max Distance | 2 km (standard), 500m (early versions) |
| Connector | MPO-12 (8 fibers: 4 TX + 4 RX) |
| Technology | Four independent 25G channels at 1310nm over parallel fibers |
Pros:
- Lower cost than LR4
- Supports breakout – one 100G port can connect to four 25G ports (e.g., 4x SFP28)
- Simple technology, widely available
Cons:
- Consumes 8 fibers – inefficient for fiber-scarce environments
- MPO connectors are larger and less common than LC
- Shorter distance than LR4 (2km vs 10km)
Best for: Data center breakout applications where fiber count is not a constraint.
100GBASE-CWDM4 (IR4)
| Aspect | Detail |
|---|---|
| Full Name | Coarse Wavelength Division Multiplexing 4-lane |
| Max Distance | 2 km |
| Connector | Duplex LC (2 fibers) |
| Technology | Four CWDM wavelengths (1271/1291/1311/1331 nm) multiplexed onto one fiber pair |
Pros:
- Uses only 2 fibers – great for existing LC duplex infrastructure
- Standard LC connectors – no cable replacement needed
- Lower cost than LR4
- Perfect for 2km campus/DC interconnect
Cons:
- Limited to 2km – cannot reach 10km
- More expensive than PSM4
- No breakout capability
Best for: Upgrading existing duplex SMF links to 100G within 2km.
100GBASE-LR4 (The Long-Reach Standard)
| Aspect | Detail |
|---|---|
| Full Name | Long-Reach 4-lane (LAN-WDM) |
| Max Distance | 10 km |
| Connector | Duplex LC (2 fibers) |
| Technology | Four LAN-WDM wavelengths (tighter spacing than CWDM) multiplexed onto one fiber pair |
Pros:
- Longest distance – 10km standard (can reach 20km+ with some modules)
- Only 2 fibers – efficient fiber utilization
- Standard LC connectors – drop-in replacement for existing LX/LH infrastructure
- Mature, proven technology – widely deployed
Cons:
- Highest cost among these options
- Higher power consumption (~4-5W)
- No breakout support
Best for: Metro networks, campus backbone, data center interconnect (DCI), and any long-haul 100G application up to 10km.
100GBASE-DR4 (Next-Generation)
| Aspect | Detail |
|---|---|
| Full Name | 4-lane Dielectric Refractive (PAM4) |
| Max Distance | 500 m |
| Connector | Duplex LC (2 fibers) |
| Technology | Single-wavelength 1310nm using PAM4 modulation (4-level amplitude) |
Pros:
- Future-proof – building block for 400G-DR4 (4x100G)
- Uses only 2 fibers with LC connectors
- Lower cost per Gbps compared to LR4 at shorter distances
- Good for 400G transition strategy
Cons:
- 500m maximum – shorter than LR4 and CWDM4
- Requires FEC (Forward Error Correction) on the host switch – not all switches support it
- Newer technology – less field-proven than LR4
Best for: New data center builds where future 400G upgrade is planned, and distances are under 500m.
Quick Decision Guide
Step 1: What is your required distance?
| Distance | Recommended Module |
|---|---|
| ≤ 500m | DR4 (if switch supports FEC) or PSM4 |
| ≤ 2km | CWDM4 (IR4) or PSM4 |
| ≤ 10km | LR4 (clear choice) |
Step 2: What is your fiber infrastructure?
| Fiber Type / Connector | Best Module |
|---|---|
| Duplex LC SMF (2 fibers) | CWDM4 (≤2km) or LR4 (≤10km) or DR4 (≤500m) |
| MPO-12 SMF (8+ fibers) | PSM4 (GR4) |
Step 3: Do you need breakout capability?
| Need | Recommendation |
|---|---|
| Yes – one 100G port to four 25G ports | PSM4 (GR4) |
| No – point-to-point 100G only | CWDM4, LR4, or DR4 |
Summary & Recommendations
| If you need… | Choose… |
|---|---|
| 10km long-distance over duplex SMF | 100GBASE-LR4 – the only standard option |
| 2km distance with existing duplex LC fiber | 100GBASE-CWDM4 (IR4) – best balance of cost and performance |
| 2km distance with MPO fiber infrastructure and breakout capability | 100G PSM4 (GR4) – lower cost, breakout ready |
| 500m distance in a new data center planning for 400G | 100GBASE-DR4 – future-proof foundation |
| Lowest cost for short links (<500m) with FEC-capable switches | 100GBASE-DR4 |
Final Word
- For 10km links → 100GBASE-LR4 is your only real choice. It’s the proven, mature standard for long-distance 100G.
- For 2km links with LC duplex fiber → 100GBASE-CWDM4 (IR4) is usually the sweet spot.
- For 2km links with MPO fiber and breakout needs → 100G PSM4 (GR4) .
- For future 400G-ready builds under 500m → 100GBASE-DR4 .